10.3.7. Replacement of additional safety locks and relay of system of injection of fuel
|
Fig. 10.5. Additional safety locks and relay of system of injection of fuel
|
The arrangement of additional safety locks and the relay of system of injection is shown on fig. 10.5, their appointment is given in tab. 10.5.
Table 10.5 Purpose of additional safety locks and relay of system of injection of fuel
You will need a key «on 10».
1. Disconnect a wire from the minus plug of the storage battery.
|
|
3. Unscrew a nut of fastening of the block of safety locks and the relay...
|
4.... also take the block from an airinflow box.
|
|
|
5. For replacement of the fused safety lock remove a protective cover...
|
6.... also take a safety lock from the contact socket of the block.
|
7. Establish in the contact socket a safety lock of the same face value, as removed.
8. In need of replacement take the relay from the assembly block, shaking it here and there, and establish the new relay.